Aerial Bundled Cable (ABC) NFC 33-209 Standard

  • Aerial Bundled Cable ABC NFC 33-209 Standard
  • Aerial Bundled Cable NFC 33-209 Standard
  • ABC NFC 33-209 Standard
  • ABC cables NFC 33-209 Standard
  • Aerial Bundled Cables NFC 33-209 Standard

Aerial Bundled Cable (ABC) NFC 33-209 Standard
Standard: NFC 33-209 Standard
Conductor: Aluminum
Insulation: XLPE
Cores: 1/2/3/4 cores
Origin: China

SKU: Made to order Categories: ,

Share on FacebookTweet about this on TwitterShare on LinkedInShare on Google+Pin on Pinterest
INQUIRY

Content:
Aerial Bundled Cable or Service Drop cable are composed of one or more concentric-lay-stranded aluminum 1350 phase conductors insulated with an extruded layer of cross-linked polyethylene compound and assembled with one neutral conductor of All Aluminum Conductors (AAC); Aluminum-Alloy Conductors 6201-T81 (AAAC); Aluminum Conductors, Steel-Reinforced (ACSR); or Aluminum Conductors, Aluminum-Clad Steel Reinforced (ACSR/AW). The neutral conductor may be bare or covered with an extruded layer of cross-linked polyethylene compound.
ABC cables have many options in terms of the number of phase conductors used, the type of neutral conductor and either it is bare or insulated.

NFC 33-209 Standard

Construction:
Phase: round stranded compressed (RM) aluminum 1350 series conductor
Neutral : round stranded compressed (RM) aluminum alloy 6201 series conductor
Insulation :XLPE insulation ,marked with digits 1/2/3
Assembly: Cores and the neutral, conductor stranded together in right-hand lay, additionally 1, 2 or 3 cores of reduced cross section can be co-stranded.

Number of Cores x Nominal Cross Section
(No.x mm^2)
Overal Diameter
(mm)
Weight
(Kg/Km)
Maximum Conductor Resistance
(Ω/Km)
Minimum Breaking Load
(kN)
Current Rating
(A)
2x10 RM12.8933.081.538
4x10 RM15.41833.081.538
2x16 RM14.81291.912.372
2x16 RN + 2x1.5 RE14.81761.910/12.1002.372
4x16 RM17.82571.912.372
4x16 RN + 2x1.5 RE17.83041.910/12.1002.372
2x25 RM182021.23.8107
2x25 RM + 2x1.5 RE182491.200/12.1003.8107
4x25 RM21.74041.23.8107
4x25 RM + 2x1.5 RE21.74511.200/12.1003.8107
2x35 RM20.82690.8685.2132
2x35 RM + 2x1.5 RE20.83160.868/12.1005.2132
4x35 RM25.15390.8685.2132
4x35 RM + 2x1.5 RE25.15860.868/12.1005.2132
2x50 RM23.43520.6417.6165
2x50 RM + 2x1.5 RE23.43990.641/12.1007.6165
1x54.6 RM + 3x25 RM21.75070.630/1.2003.8107
1x54.6 RM + 3x25 RM + 1x16 RM24.35730.630/1.200/1.9103.8/2.3107/72
1x54.6 RM + 3x25 RM + 2x16 RM29.76390.630/1.200/1.9103.8/2.3107/72
1x54.6 RM + 3x25 RM + 3x16 RM31.17050.630/1.200/1.9103.8/2.3107/72
1x54.6 RM + 3x35 RM25.16150.630/0.8685.2132
1x54.6 RM + 3x35 RM + 1x16 RM28.16800.630/0.868/1.9105.2/2.3132/72
1x54.6 RM + 3x35 RM + 2x16 RM34.37480.630/0.868/1.9105.2/2.3132/72
1x54.6 RM + 3x35 RM + 3x16 RM35.98140.630/0.868/1.9105.2/2.3132/72
1x54.6 RM + 3x35 RM + 1x25 RM28.17140.630/0.868/1.2005.2/3.8132/107
1x54.6 RM + 3x50 RM28.27410.630/0.6417.6165
1x54.6 RM + 3x50 RM + 1x16 RM31.68060.630/0.641/1.9107.6/2.3165/72
1x54.6 RM + 3x50 RM + 2x16 RM38.68750.630/0.641/1.9107.6/2.3165/72
1x54.6 RM + 3x50 RM + 3x16 RM40.49400.630/0.641/1.9107.6/2.3165/72
1x54.6 RM + 3x50 RM + 1x25 RM31.68410.630/0.641/1.2007.6/3.8165/107
1x54.6 RM + 3x70 RM339500.630/0.44310.2205
1x54.6 RM + 3x70 RM + 1x16 RM3710140.630/0.443/1.91010.2/2.3205/72
1x54.6 RM + 3x70 RM + 2x16 RM45.210830.630/0.443/1.91010.2/2.3205/72
1x54.6 RM + 3x70 RM + 3x16 RM47.311480.630/0.443/1.91010.2/2.3205/72
1x54.6 RM + 3x70 RM + 1x25 RM3710480.630/0.443/1.20010.2/3.8205/107
1x54.6 RM + 3x70 RM + 2x25 RM45.211500.630/0.443/1.20010.2/3.8205/107
1x54.6 RM + 3x70 RM + 3x25 RM47.312500.630/0.443/1.20010.2/3.8205/107
1x54.6 RM + 3x95 RM37.411760.630/0.32013.5240
1x54.6 RM + 3x95 RM + 1x16 RM41.912430.630/0.320/1.91013.5/2.3240/72

Technical Data:
Rated voltage :0.6/1kV
Test Voltage:4/50 Kv/Hz
Laying Temperature: min -5 °C
Operating Temperature : -30+90 °C
Bending Radius: 20x D of cable mm

The main advantage of ABC cable include:
1.Ease of erection and stringing
2.Practically no tree-trimming required;
3.Less maintenance

Application:
ABC cables are intended for use either as a service drop cable between a power pole and the service entrance, or as a secondary distribution cable between poles. The use of these service drop or secondary distribution cables is limited to circuits, not exceeding 600 volts phase-to-phase or 480 volts phase-to-ground, to a normal temperature rating of the service conductor temperature of 90 °C.

Aerial Bundled Cable (ABC) HD 626 S1 Standard

Aerial Bundled Cable (ABC) HD 626 S1 Standard
Standard: HD 626 S1 Standard
Conductor: Aluminum
Insulation: XLPE
Cores: 1/2/3/4 cores
Origin: China

Aerial Bundled Cable (ABC) SANS 1418 Standard

Aerial Bundled Cable (ABC) SANS 1418 Standard
Standard: SANS 1418 Standard
Conductor: Aluminum
Insulation: XLPE
Cores: 1/2/3/4 cores
Origin: China

Aerial Bundled Cable (ABC) NFC 33-209 Standard

Aerial Bundled Cable (ABC) NFC 33-209 Standard
Standard: NFC 33-209 Standard
Conductor: Aluminum
Insulation: XLPE
Cores: 1/2/3/4 cores
Origin: China

Aerial Bundled Cable (ABC) BS 7870 Standard

Aerial Bundled Cable (ABC) BS 7870-5 Standard
Standard: BS 7870
Conductor: Aluminum
Insulation: XLPE
Cores: 1/2/3/4 cores
Origin: China

Aerial Bundled Cable (ABC) ASTM B231 Standard

Aerial Bundled Cable (ABC) ASTM B231 Standard
Standard: ASTM B231
Conductor: Aluminum
Insulation: XLPE
Cores: 1/2/3/4 cores
Origin: China

Aerial Bundled Cable (ABC) ASTM B230 Standard

Aerial Bundled Cable (ABC) ASTM B230 Standard
Standard: ASTM B230
Conductor: Aluminum
Insulation: XLPE
Cores: 1/2/3/4 cores
Origin: China


Our customers have covered more than 50 countries. Export regions include Europe, North America, North Africa, Middle East, Southeast Asia, etc.

We certificate by ISO 9001:2015,ISO 14001:2015,OHSAS 18001 ,CCC Certificate ,UL certificate and so on.

We provide seaworthy cable packing, wooden drum/wooden-steel drum/ steel drum and etc, cable length can be designed according to customer needs.

We have a complete quality control system, advanced laboratory equipment, to ensure that every batch of goods sent to customers meets the quality requirements. Meanwhile, we accept testing requirements from customers and third-party testing agencies.

cables testing

We believe that an excellent professional team is the best guarantee for quality service !

Your Name :

Your Email:

Choose language