Aluminum Cable

  • Aluminum Cable
  • Aluminum Cable supplier
  • Aluminum Cable product
  • Aluminum Cable size

URD Aluminum Cable (ABC cable)
Standards :IEC/ASTM/BS/NFC/CSA/EN
Voltage: low voltage /middle voltage
Conductor: Aluminum 1350/ GI wire
Insulation :XLPE/HDPE/PE/PVC
Origin Place: China

Share on FacebookTweet about this on TwitterShare on LinkedInShare on Google+Pin on Pinterest
INQUIRY

Aluminum Cable Construction:
Phase conductors (PE or XLPE Insulated AAC ) and neutral messanges (Brae or PE/XLPE insulated AAC ,AAAC or ACSR ) are concentrically stranded .
Hard-drawn stranded aluminum wires and compacted as Core.
All cores strained equally.
Carbon-loaded XLPE insulated UV resistance acquired.

what is Aluminum Cable

  • AAC Conductor
    Concentric lay stranded Aluminum Conductor (AAC Conductor) is made up of one or more strands of hard drawn 1350 aluminum alloy.
  • AAC Conductor
    All aluminum alloy conductor (AAAC Conductor) is concentric-lay- stranded, similar in construction and appearance with 1350 grade or 6201 grade aluminum conductors. They were developed to the need of economical conductor for overhead applications requiring higher strength than that of 1350 grade aluminum conductors, but without a steel core.
  • ACSR Conductor
    All Aluminum Steel Reinforced (ACSR Conductor).Aluminum 1350 wires and the steel cores are concentrically stranded and wrapped helically around a central wire. The additional corrosion protection is available through the application of grease to the cores or infusion of the complete cable with grease.

Standards :
Aerial Bundled Cable meet or exceed the following standards: IEC , BS ,DIN , ASTM, GB standards.

Production range :

  • Sectional area : 10mm2~1500mm2
  • Voltage : 0.6/1kV,10kv,35kv
  • Cores :1-5

Aluminum Cable size chart

Aluminum Cable Application:
Aluminum wire direct burial cable has a wide variety of outdoor applications. It may be used anywhere that 600 volt secondary energy distribution is needed, including being directly buried underground. It’s also often installed in ducts and in areas where installation may be problematic.
Directly buried or installed in ducts for 600V secondary distribution.
Use in aerial bundled conductor (ABC) systems for city power grid transmission line.
Operating voltage up to 600/1000 volts.
Main for overhead single-phase and three-phase electricity distribution and other purposes.
Stable working temperature -10°C to 80°C

Aluminum Cable Advantages:
1. Economical – Good electricity property and cheaper than cooper cables.
2. Flexible – easy to install and work with distributions and other applications.
3. Safe – prevent electric short circuit and potential risk of fire.
4 .Durable – anti UV Radiation and moisture, Corrosion Resistance.
5. Aesthetically pleasing – Good finishing is guaranteed.
Adaptable – physical properties and electricity suits Africa environment and market.


Our customers have covered more than 50 countries. Export regions include Europe, North America, North Africa, Middle East, Southeast Asia, etc.

We certificate by ISO 9001:2015,ISO 14001:2015,OHSAS 18001 ,CCC Certificate ,UL certificate and so on.

We provide seaworthy cable packing, wooden drum/wooden-steel drum/ steel drum and etc, cable length can be designed according to customer needs.

We have a complete quality control system, advanced laboratory equipment, to ensure that every batch of goods sent to customers meets the quality requirements. Meanwhile, we accept testing requirements from customers and third-party testing agencies.

cables testing

We believe that an excellent professional team is the best guarantee for quality service !