Insulated cable

  • insulated cable
  • bulk insulated cable
  • cross linked polyethylene insulated cable
  • insulated cable and wire
  • shielded dual insulated cable

Insulated Wires and Cable
Standards: IEC/ASTM/BS/NFC/CSA/EN
Voltage: low voltage –high voltage
Conductor: Aluminum /Copper
Insulation: XLPE/PVC
Origin Place: China

Share on FacebookTweet about this on TwitterShare on LinkedInShare on Google+Pin on Pinterest
INQUIRY

Insulated cable Content:
XLPE/PVC Insulated Cu/Al conductor Electrical Wires and Cable:
Relative manufacturing standards: IEC60505, BS, DIN,ASTM,JIS or other standards.

Application:
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.

insulated power cable structure

Insulated cable Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV and 0.6/1kV.
2. No. Of core: Single-core, Two-cores, Three-cores, Four-cores, Five-cores, Six-cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degree.
4. D. C. Resistance of the conductor complies with the stipulations of international standard.
5. The environment temperature should be no lower than zero degree when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of cables should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:

  • For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
  • For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
  • For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.

8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable

This series includes:
Copper (aluminum) conductor, XLPE/PVC insulated ,PVC sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, PE sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA) PVC sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA), PE sheathed power cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PVC sheathed power Cables
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PE sheathed power cables

  1. Conductor:Solid or stranded copper
  2. Insulation:Cross-linked polyethylene/ polyvinyl chloride ( XLPE or PVC)
  3. Circuit Identication:The insulation shall be red, black or other colors.
  4. Filler:Polypropylene with lapped binding tape
  5. Inner Sheath:PVC(Black)
  6. Armor:Galvanized steel wire or double steel tape armor
  7. Core-covering:Binding tape
  8. Outer Sheath:PVC (Black)


Our customers have covered more than 50 countries. Export regions include Europe, North America, North Africa, Middle East, Southeast Asia, etc.

We certificate by ISO 9001:2015,ISO 14001:2015,OHSAS 18001 ,CCC Certificate ,UL certificate and so on.

We provide seaworthy cable packing, wooden drum/wooden-steel drum/ steel drum and etc, cable length can be designed according to customer needs.

We have a complete quality control system, advanced laboratory equipment, to ensure that every batch of goods sent to customers meets the quality requirements. Meanwhile, we accept testing requirements from customers and third-party testing agencies.

cables testing

We believe that an excellent professional team is the best guarantee for quality service !