LSOH Cable (Low Smoke Zero Halogen Cable)

  • LSOH cable
  • LSOH power cables
  • LSOH power cable
  • LSOH cables
  • LSOH

Low Smoke Zero Halogen Cable
Standards: IEC/ASTM/BS/NFC/CSA/EN
Voltage: 600/1000V
Conductor: Aluminum
Insulation: XLPE/PVC
Origin Place: China

Share on FacebookTweet about this on TwitterShare on LinkedInShare on Google+Pin on Pinterest
INQUIRY

LSOH Cable (Low Smoke Zero Halogen Cable) Content:
XLPE insulated Low Smoke Zero Halogen flame retardant cable has excellent flame retardant performance, during combustion only emit a small amount of smog, and smog does not have hydrogen halide and other corrosive and toxic gases, which decreases instruments and equipment corrosion and damage on the human body in the fire, but also conducive to the fire rescue work and personnel evacuation. At present, in the subway, offshore oil platform, nuclear power plants, ships and high-rise buildings and other places, all need to use non-halogen low-smoke flame retardant power cable.

According to the combustion mechanism and the performance of the cable, the non-halogen low-smoke flame retardant material is chosen according to the different parts of the cable. The structure arrangement and process flow of cable are as follows:

Conductor twisted system – internal shielding, insulation, external shielded extrusion – metal shielding – wrapping tape – inside liner – armored – outer sheath.

Among them, the wrapping tape is non-halogen low-smoke flame retardant tape. The liner layer is made of non-halogen low-smoke flame retardant filler, which can not only play the role of liner, but also can effectively separate the combustible material (XLPE) with the outside world, during burning can release water vapor, so have good flame retardant effect. Armored layer is formed by one layer of stainless steel band overlap wrapping, forming sealed thin metal layer, so in the combustion, cable outer sheath suffered heat can quickly disperse and reduce the possibility of fire breaking out. Outer sheath adopts non-halogen low smoke flame retardant polyolefin sheath material.

LSOH Cable Specification:
1.Standard: IEC 60502
2. Rated Voltage((U0/U):0.6/1kV, 3.6/6kV,3.8/6.6(7.2)kV,6/10(12)kV,6.35/11(12)kV,8.7/10(15)kV,
8.7/15(17.5)kV,12/20(22)kV,12.7/22(24)kV,12.7/22(24)kV,18/30(36)kV,19/33(36)kV

Property of XLPE Insulated LSOH Sheathed Power Cable:
1) The temperature of laying cable is not lower than 0℃.
2) Max. continuous normal operating Temperature: 90℃
3) Max. permissible temperature at short circuit (5s. at longest): 250℃.
4) Permissible bending radius:
Single core: ≥20(d+D)±5%.
Three-core:≥15(d+D)±5%
(D is the actual overall diameter of cable, and d is the actual overall diameter of conductor).

LSOH Cable Construction:
Conductor: Solid, Stranded Copper /Aluminum
Insulation : XLPE
Armoring:

  • 1.Non-Armored
  • 2. Steel Tape Armored (STA)
  • 3. Steel Wire Armored (SWA) Aluminum Wire Armored (AWA)

Sheath: LSOH material


Our customers have covered more than 50 countries. Export regions include Europe, North America, North Africa, Middle East, Southeast Asia, etc.

We certificate by ISO 9001:2015,ISO 14001:2015,OHSAS 18001 ,CCC Certificate ,UL certificate and so on.

We provide seaworthy cable packing, wooden drum/wooden-steel drum/ steel drum and etc, cable length can be designed according to customer needs.

We have a complete quality control system, advanced laboratory equipment, to ensure that every batch of goods sent to customers meets the quality requirements. Meanwhile, we accept testing requirements from customers and third-party testing agencies.

cables testing