Huaxing Cable News

Overhead cable is the main part of overhead power line. Its function is to transmit current and power. It is divided into overhead conductor and overhead insulated cable. Overhead conductors include AAC conductors, which are commonly used in distribution lines below 35KV; AAAC conductor, commonly used in distribution lines above 110kV; ACSR conductor is widely […]

Both YJV and BVV cables are suitable for outdoor street lighting and are also used to transmit electric energy. However, the models of these two cables are different. What are the differences in voltage, structure, characteristics and purpose? BVV cable: copper core PVC insulated PVC sheathed Du round cable (wire). YJV cable: XLPE insulated PVC […]

6mm-pvc-wire

With the increasing competition in the wire and cable industry, M & A integration and capital operation among large wire and cable enterprises are becoming more and more frequent. Domestic excellent wire and cable production enterprises pay more and more attention to the research on the industry market, especially the in-depth research on the change […]

We all know that wires and cables are distributed differently according to the structure of electrical conductors. Cables are divided into 1-core, 2-core, 3-core, etc. Single core cable: there is only one electrical conductor in an insulating sleeve. A wide range of main uses are home lighting equipment, power plug, central air conditioning, etc. all […]

1、 Scorch 1. Scorch phenomenon (1) The temperature is too high, or the temperature control instrument fails, causing the plastic to burn at an ultra-high temperature. (2) The glue outlet of the machine head has large smoke, strong pungent smell and crackling sound. (3) Granular scorched matter appears on the plastic surface. (4) There are […]

Power cables have long been widely used in our lives. The safety of their operation is related to our normal life and the safety of life and property. Therefore, the maintenance of cables is a vital work. The following small series will analyze what we need to know about the correct use of power cables. […]

1. External force damage According to the operation analysis in recent years, especially in places with rapid economic development, a considerable number of cable faults are caused by mechanical damage. 2. Insulation damp This situation is also very common. It usually occurs at the cable joint in the directly buried or row pipe. For example, […]

In the announcements of many suppliers of China Netcom, we can often see such a notice from Cable Enterprises: the thickness of insulation layer of power cables produced is unqualified. What is the impact of unqualified thickness of specific insulating layer on the cable? What kind of sheath is qualified? How do we make qualified […]

Shielding layer is a kind of wire with metal braid shell specially used to reduce the influence of external electromagnetic field on power supply or communication line. The shielding wire also has the function of preventing the line from radiating electromagnetic energy to a certain extent. In order to prevent the interference signal from entering […]

The main difference between the two aluminum conductors is the material. AAAC for aluminum alloy strand and ACSR for steel cored aluminum strand. From the outside, the difference is not great. ACSR cable: steel core aluminum stranded wire Steel cored aluminum strand is made of aluminum wire and steel wire, which is suitable for overhead […]

Basic theory of cable medium 2.1 introduction whether electric energy or signal is transmitted by wires and cables, the purpose is to use it to transmit current to the power receiving equipment or power receiving end. To achieve this, a conductor is required to transmit the required load current. It is also important to keep […]

AAC (all aluminum conductor) is also called aluminum strand ACSR: aluminum conductor steel reinforced ABC: overhead bundle cable (with insulation, bundle several together) AAAC: all aluminum alloy conductor AAC / all aluminum conductor These conductors are suitable for spans of wooden poles, transmission towers and other structures that do not require tensile strength and rated […]

The so-called “partial discharge” refers to a kind of discharge in which only some areas in the insulation system discharge without forming a penetrating discharge channel under the action of an electric field. The main reason for partial discharge is that when the dielectric is uneven, the electric field strength borne by each area of […]

Fireproof wires and cables are the general name of wires and cables with fireproof performance. They are usually divided into flame-retardant wires and cables and fire-resistant wires and cables. For some designers just engaged in electrical design, it is essential to understand some cable characteristics in the industry. Let’s talk about the difference between flame-retardant […]

Aluminum core reinforcement is a product twisted by single-layer or multi-layer aluminum wires. In the process of use, its structure is very simple to ensure that its installation time can be greatly reduced, which provides convenience for our life. As for transmission, its transmission capacity is very large. Both the rivers and lakes across the […]

Speaking of wires and cables, we have to mention copper and aluminum in their main materials. The question is, what is the difference between copper core and aluminum core wires and cables? Which is better? Let’s get to know~ There are several ways to distinguish whether the wire core is copper core or aluminum core […]

1、 Greedy for low prices. This is a common misunderstanding of many users and even some enterprises in the exercise of wires and cables. In order to save money and ignore safety, some users choose low-quality wires and cables with low price, no guarantee of quality and great potential accidents. We know that due to […]

The term ACSR stands for “steel cored aluminum conductor”. It is a stranded conductor, including many aluminum conductor layers on the simulated steel wire core. The steel wire core here is a single steel wire depending on the size. These can be used for different zinc coatings, such as grade A, B and C, to […]

AAAC Conductor Size Chart

AAAC Conductor BS 3242 Size Chart & Full Form AAAC Conductor DIN 48201 Size Chart & Full Form AAAC Conductor BS EN50182 Size Chart & Full Form AAAC Conductor ASTM B399 Size Chart & Full Form AAAC Conductor NFC 34125 Size Chart & Full Form AAAC conductor is bare concentric-lay-stranded conductor made from round aluminum alloy 6201 -T81 […]

AAC Conductor Size Chart

AAC Conductor Size Chart & Full Form AAC Conductor IEC 61089 Size Chart & Full Form AAC Conductor DIN 48201 Size Chart & Full Form AAC Conductor CSA C49 Size Chart & Full Form AAC Conductor BS 215 :1970 / EN 50182 Size Chart & Full Form AAC Conductor ASTM B231M Size Chart & Full […]

ACSR Conductor Size Chart

ACSR Conductor ASTM B239 Size Chart & Full Form ACSR Conductor CSA C49-1965 Size Chart & Full Form ACSR Conductor IEC 61089 – 1997 Size Chart & Full Form ACSR Conductor EN 50182 BS 215 : 1970 Size Chart & Full Form ACSR Conductor DIN 48 Size Chart & Full Form ACSR Conductor SS 424 […]

Basic structure and classification of power cables

Basic structure The basic structure of power cable consists of core (conductor), insulating layer, shielding layer and protective layer. (1) Core The core is the conductive part of power cable, which is used to transmit electric energy and is the main part of power cable. (2) Insulating layer The insulation layer is to separate the […]

Alloy power cables are replacing traditional cables

Mine armored control cable MKVV22,MKVV32  2*0.5,3*0.75,4*4,——37*1.5mm Armored control cable KVV22,KVV32,KVVR22  2*0.5,3*0.75,4*4,——37*1.5mm Armored shielded control cable KVVP-22,RVVP-22,KVVRP-22,KVVP2-22,KVVRP2-22 2*0.5,3*0.75,4*4,——37*1.5mm Armored flame retardant control cable ZR-KVV22,ZR-KVV32,ZR-KVVR22 2*0.5,3*0.75,4*4,——37*1.5mm Armored flame retardant shielded control cable ZR-KVVP22,ZR-KVVRP22,ZR-KVVP2-22,ZR-KVVRP2-22 2*0.5,3*0.75,4*4,——37*1.5mm Armored shielded control cable KVVP-22,RVVP-22,KVVRP-22,KVVP2-22,KVVRP2-22 2*0.5,3*0.75,4*4,——37*1.5mm Armored flame retardant control cable ZR-KVV22,ZR-KVV32,ZR-KVVR22 2*0.5,3*0.75,4*4,——37*1.5mm Armored flame retardant shielded control cable ZR-KVVP22,ZR-KVVRP22,ZR-KVVP2-22,ZR-KVVRP2-22 2*0.5,3*0.75,4*4,——37*1.5mm Armored communication cable HYA22, hya23, hya53, hyv22, HYV23, 5 pairs, […]

Alloy power cables are replacing traditional cables

1. Reliable safety performance. The Alloy power cable has been strictly certified by UL in foreign countries and has been used in the United States, Canada, Mexico and other countries for 40 years without any problems. Based on the introduction of advanced technology from the United States, the alloy cable is independently developed and has […]

The Basic Structure of Power Cables

The Basic Structure of Power Cables The conductor is extruded and covered with an insulating layer, such as an overhead insulated cable, or several-core stranded (corresponding to the phase, neutral and ground wires of the power system), such as an overhead insulated cable with more than two cores, or an additional sheath, such as plastic/ […]

Make 3 types of conductors work for you

Bare conductor generally refers to conductive material without insulation and sheath. The main 3 types of conductors including AAC conductor, AAAC conductor and ACSR conductor. 1.All Aluminum Conductor (AAC) This bare concentric-lay stranded conductor is constructed with a straight round central wire surrounded by one or more layers of helically layed wires. These wires are […]

prevent abrasion of conductor 3

In the stringing construction of 66kV and above transmission lines, it is often encountered that some conductors are worn due to various reasons in the construction, which need to be handled, which is inconvenient for the construction. According to the previous construction experience of transmission line stringing, the following research and methods of conductor abrasion […]

power cable from control cable

Power cable is the backbone of power system, which is used to transmit and distribute large-scale electric energy. The rated voltage is generally 0.6/1kv and above. The control cable directly transmits the electric energy to the power supply connection of various electrical equipment and appliances, and its rated voltage is 450 / 750V. This makes […]

Main models of aluminum alloy cable

The main models of aluminum alloy cable are ZA-AC90(YJLHV60.YJLHV8), ZB-ACWU90(YJLHV62.YJLHV82), ZC-TC90(YJLHV). ZC-TC90 XLPE insulated PVC sheathed aluminum alloy cable AC90 changes the traditional sheath into interlocking armor. Acwu90 adds a layer of PVC protective sheath on the basis of AC90. The actual structure of tc90 is similar to that of traditional aluminum cable yjlv, and […]

national standard cable

When choosing the cable, choose the cable according to the use of the site, don’t covet cheap. Think that the cable price is cheap and can ensure that it is the national standard, nine out of ten are playing edge ball. Cheat the users who are not professional and don’t understand the industry. The quality […]